Skip to main content

Zero-Defect Metrology & Quality Protocol

Rigorous Quality Assurance & CMM Inspection

Industrial components and multi-cavity injection molds demand absolute repeatability. Our ISO 9001:2015 certified quality management system guarantees that every micron complies with your CAD specification.

01

Raw Material Virginity & MFI Verification

Incoming polymer pellets (POM, PA66, PC, PP) undergo automated Melt Flow Index (MFI) testing, moisture titration, and ash content validation prior to hopper loading.

ASTM D1238 / ISO 1133
02

First Article Inspection (FAI) & CMM Mapping

Before serial production, T1 samples undergo full 3D coordinate measuring on our Zeiss bridge CMM to establish baseline CPK and dimensional conformity against CAD blueprints.

AS9102 / ISO 20457 Grade 130
03

In-Process SPC Hourly Statistical Control

Quality engineers perform dimensional, weight, and cosmetic spot audits every 60 minutes on active presses with calibrated digital micrometers and pin gauges.

Six Sigma CPK > 1.67 Protocol
04

Final Pre-Dispatch QA Certification

Every dispatch consignment includes an itemized Certificate of Analysis (COA) and dimensional inspection sheet signed by our Chief Quality Inspector.

ISO 9001:2015 Certified Release

Verified Metrology Equipment

Zeiss CMM Bridge & 2.5D Optical Profile Verification

We do not guess tolerances. Every mold electrode, cavity block, and precision textile component is verified against 3D CAD nominal geometry in our temperature-stabilized metrology room (20°C ± 0.5°C). Full statistical histograms and pass/fail reports accompany all exported shipments.

Linear Accuracy 1.4 µm + L/350
Temperature Stability 20°C ± 0.5°C
Calibration Standard NIST / DKD Traceable
BINYAMIN TRADERS QA LAB CERT-2026-QA
Inspection Part:
BT-TX-SP101 (Dyeing Tube)
Lot Size / Sample:
10,000 pcs / 32 pcs FAI
Material Batch:
Modified PP High-Impact #849
DimensionNominalActualStatus
OD Center54.00054.012PASS (+0.012)
Length170.000169.988PASS (-0.012)
Radial Runout< 0.0300.018PASS
Inspector: M. Arshad (QC-Lead) DISPATCH APPROVED